TetraCon 325 CONDUCTIVITY CELLS
Conductivity electrodes for field conductivity and salinity measurements.
Conductivity cells, conductivity electrodes FEATURES:
  • Large measuring range
  • Built-in temperature sensor
  • Highly precise measurements
  • Robust unbreakable epoxy body
To Order Call 1-800-876-1172
Conductivity Cells Options & Prices
On this page:

Conductivity Cells Product Description
Conductivity Cells Product Applications
Conductivity Cells Specifications
Conductivity Cells Options & Prices

Downloads (PDF):

Conductivity Cells Brochure
Conductivity Cells Manual*

*May take several minutes to download, depending on your internet connection speed.
Additional Information:

Measuring hardness using TDS or Conductivity cell measurments
Conductivity Cells calibration explained
Product Support
Water Quality Sensors

Conductivity Cells Product Description
The TetraCon® 4-electrode conductivity cells set a new standard for professional conductivity measurements.  In comparison with conventional measuring cells with 2 electrodes, the TetraCon® 325 conductivity cell offers numerous technical advantages.  The conductivity electrode was designed to optimize the conductivity cell geometry providing you with the highest accuracy electrode possible.  The conductivity cell's design allows it to have an extremely large measuring range using a single electrode and meter combination for most applications.  Long-term cell constant stability is a result of the conductivity cell's high-quality abrasion-resistant graphite electrode construction.  The conductivity cell's design also allows for a very shallow immersion depth, 1.4 inches (36 mm), with a virtually unbreakable robust epoxy body.  Additional design features mean that the conductivity cell's measurements are not affected by cable influences, polarization effects or contact with any surfaces.  All TetraCon® 4-electrode conductivity cells come with a built-in temperature sensor to automatically compensate the output to your sample's temperature.  The automatic resistance compensation feature provides you with accurate measurements even with a dirty conductivity cell.

conductivity cell measurement chart
Conductivity cell measurements
Conductivity is a parameter used to measure the ionic concentration and activity of a solution.  The more salt, acid or alkali in a solution, the greater its conductivity.  The unit of conductivity is S/m, often also S/cm.  The scale for aqueous solutions begins with pure water at a conductivity of 0.05 uS/cm (77 °F /25 °C).  Naturally occurring waters such as drinking water or surface water have a conductivity in the range 100 - 1000 uS/cm.  At the upper end of the chart some acids and alkalines can be found.

Conductivity cell measurements are used for a wide range of applications such as the production of ultrapure water or determining the salinity of sea water.

Conductivity is measured by using a conductivity cell to make a measurement of the electrical resistance.  The simplest kind of measuring cell used consists of two similar electrodes.  An alternating voltage applied to one of the conductivity electrodes causes the ions in the solution to migrate towards the electrodes.  The more ions in the solution, the greater the current which flows between the conductivity electrodes.  The conductivity meter measures the current produced by the conductivity cell and uses Ohm's law to calculate first the conductance of the solution and then - by taking the cell data into account - the conductivity.
Conductivity Cells Applications
The TetraCon 325 Conductivity Cells are ideal for monitoring ground water, rivers, lakes, streams, swimming pools, and industrial water applications including juices, electroplating, and pharmaceutics.  With the Cond 3110 handheld field meters the conductivity cells are ideal for routine field measurements.  The Cond 3210 meter raises the performance level of the conductivity cells to a point where they are recommended for highly precise control, quality assurance, and field measurements including the ability to make TDS measurements.  With the Cond 1970i rugged field meters the conductivity cell measurements can be controlled with a computer, stored in the 800 dataset memory, and supported using GLP requirements.
Conductivity Cells Specifications
Measuring Principle: 4-electrode conductivity cell measurement
Conductivity Cell Constant: 0.475 cm-1 ±1.5 %
Temperature Sensor: Integrated NTC 30 (30kΩ/77°F (25°C))
Measurement Range: 1uS/cm to 2S/cm
Temperature Range: 23 to +176°F (-5 to +80°C)
Maximum Allowed Overpressure: 29 psi (2 bar)
Immersion Depth: 1.4 inches min/length of cable max (36 mm min/length of cable max)
Operating Position: Any
Storage Temperature: 32 to +122°F (0 to +50°C)
Recommended Storage Method: Air
Temperature Response:
      t99 (99 % of indication of end value after) < 20 s
Accuracy of Temperature Sensor: + 0.2 K
Cable Length: Varies
Cable Plug: 8 pin socket
Cable Diameter: 0.24 inches (6 mm)
Material:
     Thermistor Housing: Graphite
     Conductivity Electrodes: Graphite
     Shaft: Epoxy
     Connection head: POM
Size of Probe: 4.7 inches L x 0.6 inches Dia. (120 mm L x 15.3 mm Dia.)
Weight: 0.3 lb. (135 g) w/4.9 ft (1.5 m) of cable
Conductivity Cells Options & Prices
Prices listed are for United States and Canada only.  Call or e-mail us for pricing in other countries.
Terms and Conditions

TetraCon 325 Conductivity Cell (PN# 301960)
4-electrode conductivity cell with built-in temperature sensor, 4.9 ft (1.5 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
TetraCon 325-3 Conductivity Cell (PN# 301970)
4-electrode conductivity cell with built-in temperature sensor, 9.8 ft (3 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
TetraCon 325-6 Conductivity Cell (PN# 301971)
4-electrode conductivity cell with built-in temperature sensor, 19.8 ft (6 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
TetraCon 325-10 Conductivity Cell (PN# 301972)
4-electrode conductivity cell with built-in temperature sensor, 33 ft (10 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
TetraCon 325-15 Conductivity Cell (PN# 301973)
4-electrode conductivity cell with built-in temperature sensor, 49.5 ft (15 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
TetraCon 325-20 Conductivity Cell (PN# 301974)
4-electrode conductivity cell with built-in temperature sensor, 65.6 ft (20 m) cable and waterproof plug, cell constant K=0.475 cm-1
Call
CONDUCTIVITY CELL CALIBRATION SOLUTIONS
KS 5 uS Conductivity Cell 5 uS/cm Solution (PN# 300580)
Calibration standard 5 ÁS/cm, shelf life 1 year, NIST traceable, accuracy ±2%.
Call
KS 100 uS Conductivity Cell 100 uS/cm Solution (PN# 300578)
Calibration standard 100 ÁS/cm, shelf life 2 years, NIST traceable, accuracy ±3%.
Call
E-SET Trace uS Conductivity Cell Calibration Set (PN# 300572)
Calibration set, 6 bottles with 50 ml calibration and control standard each, KCl 0.01 M/l traceable to PTB/NIST.
Call
6R/SET/LAB1 Conductivity Cell Calibration Set (PN# 302870)
Test set for checking all conductivity meters with waterproof 8-pin socket according to ISO 9000.
Call
RELATED PRODUCTS
Conductivity Electrodes
Conductivity electrodes for various applications.
Pricing
2CA102 Cond 3110 Set Handheld Conductivity Meter Set
Includes meter, TetraCon 325-3 probe, case & accessories.
Call
Lab 960 Benchtop Conductivity Meter Pricing
ProLab 4000 Multiparameter Benchtop Meter Pricing
EC30A Conductivity Tester
Includes meter and conductivity cell, batteries, and instruction manual.
Pricing
EC300ACC Field Conductivity Meter Kit
Includes field conductivity meter, cable with attached conductivity/temperature probe, and hard sided case.
Pricing
EC500 Pocket pH/Conductivity Tester
Includes electrode, protective sensor cap, sample cup with cap, four 1.5V SR44W batteries, and a 48 inch (1.2m) neckstrap.
Pricing
EC510 Pocket pH/Conductivity Tester Kit
Includes an EC500 portable conductivity meter with sensor, 84uS, 1413uS, 12880uS calibration standards, pH buffer pouches (1 each of 4, 7, 10pH plus rinse solution), weighted base, protective sensor cap, 3 sample cups, four 1.5V SR44W batteries, carrying case, and a 48 inch (1.2m) neckstrap.
Pricing
WQ-Cond Conductivity Sensor
4-20mA output.  Includes 25 ft of cable.
Pricing
WQ Water Quality Sensors Pricing