Global Water In the US, call toll free: 1-800-876-1172
International phone: 1-979-690-5560
Fax: 1-979-690-0440
E-mail: Globalw*globalw.com
Follow @GlobalWater2  Like us on Facebook
HOME   ORDERING NEWS ABOUT US SUPPORT CONTACT DISTRIBUTORS LINKS  
 
Water Level

Water Flow

Water Samplers

Water Quality

Weather

Remote Monitoring

Industrial Control

SCIENCELINE ISE (ION SELECTIVE ELECTRODES)
Ion selective electrodes for specific parameter measurements.
ion selective electrodes
Fluoride combination ion selective electrode shown.
FEATURES:
  • Wide range of ISE parameters
  • Robust, durable, and easy to clean
  • Combination or half-cell electrodes available
To Order Call 1-800-876-1172
Ion selective electrodes Options & Prices
On this page:

Ion selective electrodes Product Description
Ion selective electrodes Specifications
Ion selective electrodes Options & Prices

Downloads (PDF):

Ion selective electrodes Brochure
Fluoride ISE ion selective electrodes Manual*
Chloride ISE ion selective electrodes Manual*
Nitrate ISE ion selective electrodes Manual*
Potassium ISE ion selective electrodes Manual*
Calcium ISE ion selective electrodes Manual*
Cyanide ISE ion selective electrodes Manual*
Sulfide ISE ion selective electrodes Manual*
Iodide ISE ion selective electrodes Manual*
Bromide ISE ion selective electrodes Manual*
Copper ISE ion selective electrodes Manual*
Lead ISE ion selective electrodes Manual*
Ammonia ISE ion selective electrodes Manual*
Sodium ISE ion selective electrodes Manual*
ISE Reference electrodes Manual*

*May take several minutes to download, depending on your internet connection speed.
Additional Information:

ISE ion selective electrode maintenance instructions
Product Support

ISE Ion Selective Electrodes Product Description
In research and development, manufacturing, and quality control, SI Analytics ScienceLine ISE ion selective electrodes have long since become standard for the most demanding measuring tasks.  Each ion selective electrode has an individual serial number making documentation easier and more traceable.  The ScienceLine ISE ion selective electrodes from SI Analytics not only have high measurement accuracy, stability, and long service life, but are highly adaptable to your measuring requirements.

The ScienceLine ISE ion selective electrodes are designed for many different environments from general monitoring and control of plants to examination of samples in quality control labs.  There are two ion selective electrode families the 60 family and the 1100 family.  The 60 series ion selective electrodes are combination electrodes designed for direct measurement use.  These ion selective electrodes can be used to test for a wide variety of ions including fluoride, chloride, potassium, cyanide, sulfide, iodide, bromide, copper, and lead.  The 1100 series ion selective electrodes are half-cell electrodes designed for titration measurements in combination with a reference electrode.  The ScienceLine also offers a special sodium ISE ion selective electrodes.  The sodium ISE ion selective electrodes are combination electrodes designed to measure sodium in the range of 0 to 6 pNa.
ISE Ion Selective electrodes Specifications
60 and 1100 Series ISE Specifications
Model # Parameter Temperature Range °F (°C) pH Range Measurment Range (mg/l) Reproducibility Membrane Resistance
F 60/1100 A: Fluoride 32 to 176 (0 to 80) 5 to 7 0.02 to saturation ± 2% 0.15 to 0.2 MΩ
Cl 60: Chloride 32 to 176 (0 to 80) 2 to 12 2 to 35,000 ± 2% <1 MΩ
NO 60: Nitrate 32 to 104 (0 to 40) 2.5 to 11 0.4 to 62,000 ± 2% 1 to 5 MΩ
K 60: Potassium 32 to 104 (0 to 40) 2 to 12 0.04 to 39,000 ± 2% <50 MΩ
Ca 60/1100 A: Calcium 32 to 104 (0 to 40) 2.5 to 11 0.02 to 40,000 ± 4% 1 to 4 MΩ
CN 60: Cyanide 32 to 176 (0 to 80) 0 to 14 0.2 to 260 ± 2% <30 MΩ
Ag-S 60: Sulfide 32 to 176 (0 to 80) 2 to 12 0.01 to 108,000 Ag, 0.003 to 32,000 S ± 2% for Ag, 4% for S <1 MΩ
I 60: Iodide 32 to 176 (0 to 80) 0 to 14 0.006 to 127,000 ± 2% <0.1 MΩ
Br 60: Bromide 32 to 176 (0 to 80) 1 to 12 0.4 to 79,000 ± 2% <1 MΩ
Cu 60/1100 A: Copper 32 to 176 (0 to 80) 2 to 6 0.0006 to 6,400 ± 4% <1 MΩ
Pb 60/1100 A: Lead 32 to 176 (0 to 80) 4 to 7 0.2 to 20,000 ± 4% <1 MΩ
Shaft: Plastic, 1/2 inch (12 mm Ø)
Length: 4.7 inch (120 mm), not including connection head
Connction: 60 series: plug head, 1100 series: fixed cable 3.3 ft (1m) DIN plug

Na 61 Sodium ion selective electrode
Measurement Range: 0 to 6 pNa
Temperature Range: 14 to +176°F (-10 to +80°C)
Shaft: glass, 1/2 inch (12 mm Ø)
Shaft Length (not including plug head): 6.7 in (170 mm)
Zero Point: pNa = 2.0
Diaphragm: Platinum
Reference System: Silamid
Reference Electrolyte: KCl 3 mol/l
Shape of Glass Membrane: Sphere
Connection: Plug head
ISE Ion Selective electrodes Options & Prices
Prices listed are for United States and Canada only.  Call or e-mail us for pricing in other countries.
Terms and Conditions

SCIENCELINE COMBINATION ISE ION SELECTIVE ELECTRODES
ScienceLine F 60 Fluoride Ion Selective Electrode (PN# 285130340)
Plug head (recommended cable: L 1 A), ISE for the determination of fluoride ions.  Membrane material - pressed piece of ion crystal.
Pricing
ScienceLine Cl 60 Chloride Ion Selective Electrode (PN# 285130350)
Plug head (recommended cable: L 1 A), ISE for the determination of chloride ions.  Membrane material - pressed piece of ion crystal.
Pricing
ScienceLine NO 60 Nitrate Ion Selective Electrode (PN# 285130360)
Plug head (recommended cable: L 1 A), ISE for the determination of nitrate ions.
Pricing
ScienceLine K 60 Potassium Ion Selective Electrode (PN# 285130370)
Plug head (recommended cable: L 1 A), ISE for the determination of potassium ions.
Pricing
ScienceLine Ca 60 Calcium Ion Selective Electrode (PN# 285130380)
Plug head (recommended cable: L 1 A), ISE for the determination of calcium ions.
Pricing
ScienceLine CN 60 Cyanide Ion Selective Electrode (PN# 285130390)
Plug head (recommended cable: L 1 A), ISE for the determination of cyanide ions.
Pricing
ScienceLine Ag-S 60 Sulfide Ion Selective Electrode (PN# 285130400)
Plug head (recommended cable: L 1 A), ISE for the determination of sulfide ions.  Stability of measured value - <0.2 mV/min over the measureing range.
Pricing
ScienceLine I 60 Iodide Ion Selective Electrode (PN# 285130410)
Plug head (recommended cable: L 1 A), ISE for the determination of iodide ions.
Pricing
ScienceLine Br 60 Bromide Ion Selective Electrode (PN# 285130420)
Plug head (recommended cable: L 1 A), ISE for the determination of bromide ions.
Pricing
ScienceLine Cu 60 Copper Ion Selective Electrode (PN# 285130430)
Plug head (recommended cable: L 1 A), ISE for the determination of copper ions.
Pricing
ScienceLine Pb 60 Lead Ion Selective Electrode (PN# 285130440)
Plug head (recommended cable: L 1 A), ISE for the determination of lead ions.
Pricing
SCIENCELINE HALF-CELL ISE ION SELECTIVE ELECTRODES
ScienceLine Ca 1100 A Calcium Ion Selective Electrode (PN# 285216314)
3.28 ft (1 m) fixed cable with DIN plug, ISE for the determination of calcium ions.  Requires reference electrode.
Pricing ion selective electrodes
ScienceLine Cu 1100 A Copper Ion Selective Electrode (PN# 285216312)
3.28 ft (1 m) fixed cable with DIN plug, ISE for the determination of copper ions.  Requires reference electrode.
Pricing
ScienceLine F 1100 A Fluoride Ion Selective Electrode (PN# 285216313)
3.28 ft (1 m) fixed cable with DIN plug, ISE for the determination of fluoride ions.  Membrane material - pressed piece of ion crystal.  Requires reference electrode.
Pricing
ScienceLine Pb 1100 A Lead Ion Selective Electrode (PN# 285216315)
3.28 ft (1 m) fixed cable with DIN plug, ISE for the determination of lead ions.  Requires reference electrode.
Pricing
SCIENCELINE ISE ION SELECTIVE REFERENCE ELECTRODES
R 503/P ISE Half-Cell Reference Electrode (PN# 106570)
Reference electrode with electrolyte bridge and 3.28 ft (1 m) fixed cable, US plug, 0.078 inch (2 mm) diameter.
Call
R 503/D ISE Half-Cell Reference Electrode (PN# 106570)
Reference electrode with electrolyte bridge and 3.28 ft (1 m) fixed cable, banana plug, 0.16 inch (4 mm) diameter.
Call
SCIENCELINE SODIUM ISE ION SELECTIVE ELECTRODES
ScienceLine Na 61 Sodium Ion Selective Electrode (PN# 285100026)
ISE for the determination of sodium ions.
Pricing
SCIENCELINE ISE ION SELECTIVE ELECTRODES PLUG HEAD CABLES
L 1 A Ion Selective Electrode Cable (PN# 285122456)
Coaxial electrode plug, 3.28 ft (1 m) coaxial cable, DIN instrument plug.
Pricing
SCIENCELINE ISE ION SELECTIVE ELECTRODE ACCESSORIES
S/FK Polishing strips for Ion Selective Electrodes (PN# 180130)
For use with F 60/1100, Cl 60, Ca 60/1100, CN 60, Ag-S 60, I 60, Br 60, Cu 60/1100, and Pb 60/1100 ISEs.
Call
SCIENCELINE ISE ION SELECTIVE ELECTRODE SOLUTIONS
L 300 potassium chloride solution 3 mol/l, sterilized, 1000 ml DURAN® bottle (PN# 285138554)
For use with Na 61 ISE.
Pricing
L 3004 potassium chloride solution 3 mol/l, sterilized, 250 ml DURAN® bottle (PN# 285138427)
For use with Na 61 ISE.
Pricing
L 3008 potassium chloride solution 3 mol/l, 50 mL (PN# 285138505)
For use with Na 61 ISE.
Pricing
L 510 cleaning solution pepsin/hydrochloric acid, 1000 ml DURAN® bottle (PN# 285138538)
For use with Na 61 ISE.
Pricing
L 5104 cleaning solution pepsin/hydrochloric acid, 250 ml DURAN® bottle (PN# 285138295)
For use with Na 61 ISE.
Pricing
ELY/BR/503 electrolyte solution, 250 ml bottle (PN# 106575)
For use with R 503 reference electrodes and all 60 series ISEs except NO 60 and K 600 ISEs.
Call
ELY/BR/503/N electrolyte solution, 250 ml bottle (PN# 106576)
For use with NO 60 ISE.
Call
ELY/BR/503/K electrolyte solution, 250 ml bottle (PN# 106577)
For use with K 60 ISE.
Call
TISAB ISE Sample Conditioning Solution, four 1 L bottles (PN# 140100)
For use with F 60/1100 ISE.
Call
ISA/FK ISE Sample Conditioning Solution, two 250 ml bottles (PN# 140110)
For use with Cl 60, Ag-S 60, I 60, Br 60, and Pb 60/1100 ISEs.  NaNO3, 5 mol/l.
Call
TISAB/NO3 ISE Sample Conditioning Solution, four 1 L bottles (PN# 150120)
For use with NO 60 ISE.
Call
ISA/K ISE Sample Conditioning Solution, 250 ml bottle (PN# 106580)
For use with K 60 ISE.
Call
ISA/Ca ISE Sample Conditioning Solution, 250 ml bottle (PN# 140120)
For use with Ca 60 and Cu 60/1100 ISEs.  KCl, 4 mol/l.
Call
MZ/NH3/CN ISE Sample Conditioning Solution, 250 ml bottle (PN# 150130)
For use with CN 60 ISE.  NaOH, 10 mol/l.
Call
SCIENCELINE ISE ION SELECTIVE ELECTRODE STANDARDS
ES/F Standard solution for Ion Selective Electrode (PN# 120160)
For use with F 60 ISEs.  10 g/l F, 1 L bottle.
Call
ES/Cl Standard solution for Ion Selective Electrode (PN# 120140)
For use with Cl 60 ISEs.  10 g/l Cl, 1 L bottle.
Call
ES/NO Standard solution for Ion Selective Electrode (PN# 120220)
For use with NO 60 ISEs.  10 g/l NO, 1 L bottle.
Call
ES/K Standard solution for Ion Selective Electrode (PN# 120210)
For use with K 60 ISEs.  10 g/l K, 1 L bottle.
Call
ES/Ca Standard solution for Ion Selective Electrode (PN# 120200)
For use with Ca 60/1100 ISEs.  10 g/l Ca, 1 L bottle.
Call
ES/I Standard solution for Ion Selective Electrode (PN# 120180)
For use with I 60 ISEs.  10 g/l I, 1 L bottle.
Call
ES/Br Standard solution for Ion Selective Electrode (PN# 120120)
For use with Br 60 ISEs.  10 g/l Br, 1 L bottle.
Call
ES/Cu Standard solution for Ion Selective Electrode (PN# 120190)
For use with Cu 60/1100 ISEs.  10 g/l Cu, 1 L bottle.
Call
ES/Pb Standard solution for Ion Selective Electrode (PN# 120100)
For use with Pb 60/1100 ISEs.  10 g/l Pb, 1 L bottle.
Call
RELATED PRODUCTS
ProLab 1000 Bench top pH meter Pricing
ProLab 3000 Laboratory pH meter Pricing
ProLab 4000 Multiparameter Benchtop Meter Pricing
BlueLine Gel Filled pH Electrodes (PN# Varies)
Robust gel filled pH electrodes for basic pH measurements.
Pricing
IoLine Tris Compatible pH Electrodes (PN# Varies)
Tris compatible glass pH electrodes without integrated temperature sensor for demanding pH measurements.
Pricing
IoLine High Performance pH Electrodes (PN# Varies)
High performance glass pH electrodes for demanding pH measurements.
Pricing
Lab 850 Benchtop pH meter Pricing
inoLab® 7110 wastewater pH meter Call
pH10A Handheld pH Meter Pricing
pH100CCA Handheld pH Meter Kit
Includes handheld pH meter, cable with attached pH/temperature probe, and hard sided case.
Pricing
PHT-810 Field pH Tester Pricing
EC500 Portable Field pH/Conductivity Meter
Includes electrode, protective sensor cap, sample cup with cap, four 1.5V SR44W batteries, and a 48 inch (1.2m) neckstrap.
Pricing
EC510 Portable Field pH/Conductivity Meter Kit
Includes an EC500 portable conductivity meter with sensor, 84uS, 1413uS, 12880uS calibration standards, pH buffer pouches (1 each of 4, 7, 10pH plus rinse solution), weighted base, protective sensor cap, 3 sample cups, four 1.5V SR44W batteries, carrying case, and a 48 inch (1.2m) neckstrap.
Pricing
2V00-1011 VARIO pH Waterproof Field pH Meter Call
3A30-110 1970i Portable field pH meter w/universal power supply Call
WQ201 pH Sensor Pricing
WQL-pH pH Datalogger
Included: pH datalogger, PC-program WQL-Log, USB cable, Li battery, shackle, and hex wrench.
Call
WQ Water Quality Sensors Pricing
Click here to learn about the brands in the Analytics family.
 Xylem Legal Disclaimer | Privacy Policy